REVO FC 80

Spectral-Domain OCT | Color Fundus Camera

OCT made simple.

The REVO FC combines the world’s fastest SD-OCT with a non-mydriatic color fundus camera. Featuring our all-new AccuTrack™ real-time hardware-based eye tracker. Operating is as simple as the push of a button.

Spectral-Domain OCT

Fully automated capture with the push of the START button.

Moving OCT innovation forward. OPTOPOL pioneered the first Spectral Domain OCT technology 20 years ago. Our background allows us to provide an unparalleled experience to both patients and eye care professionals. Get the best of both worlds with ultra-high quality scans in an easy-to-use interface. 

  • Provides both Posterior and Anterior scan capabilities.
  • Combine one-touch exams with preset scan combinations for streamlined workflows.
  • Progression analysis available for detailed analysis over time.
  • Add-on software modules to increase the efficiency of your OCT device.

Non-Myd Color Fundus Camera

Capture high-resolution 45° true color retinal imaging. 

The REVO FC OCT series adds a 12.3 MP Fundus Camera, capable of capturing ultra-high quality color images. The REVO FC series Fundus Camera is fully automated and easy to use.

  • Auto-alignment, auto-focus, auto-flash, auto-capture with the push of a button.
  • Capture high resolution fundus images with a pupil size as small as 3.3 mm.
  • Toolkit of various fundus image processing tools.
  • Deliver detailed photos of one or both eyes as well as a chronological comparison.
  • Save time by attaching a single fundus photo to several OCT scans.

Take your OCT to the next level

REVO FC 80

AccuTrack™

Our hardware-based eye tracker, compensates for blinks, loss of fixation and involuntary eye movements during scans reducing artifacts.

Auto Functions

Simplifying operation with the push of a button to auto-postion, auto-align, auto-focus, and auto-capture.

AI DeNoise

An advanced artificial intelligence (AI) algorithm removes noise from the tomogram for the highest image quality.

Custom Scan Protocols

Save time and never miss a scan. Create a custom preset group of scans and let the REVO capture all scans in order.

Motion Correction

The software-based motion correction (MC) compensates for involuntary eye movements and blinks by capturing two scans and generating a motion corrected scan when necessary.

Structure + Function (S+F)

Comprehensive glaucoma solution that combines REVO OCT and PTS Visual Field results. S+F takes the diagnostic approach of the Hood report.

Progression Analysis

Gather baselines and follow-ups to monitor and manage disease progression in posterior and anterior scans.

Network Integration

A proficient networking solution with DICOM and EMR capabilities. Quickly and easily export to a desired location..

Follow disease progression

Full Range

With scans presenting New Extended DepthTM software, based on our Full Range technology, provides scans of increased depth for reliable and convenient observation of challenging cases. With scans presenting extended depth, this new imaging mode is perfect for diagnosing even highly myopic patients.

standardize scans performed

Connectivity

REVO offers an excellent networking solution that allows doctors to view and manage multiple examinations from review stations in your practice. The system comes with the latest version of Windows PRO and can easily export in PDF, JPEG and DICOM formats to your network or EHR.

Follow disease progression

Progression Analysis

Quickly view a chronological set of exams for analysis of changes in morphology, quantified progression maps, and progression trends.

standardize scans performed

Custom Scan Protocols

Save time and never miss a scan. Combine any scan type into a pre-set group. Choose a group of scans and set the order, the REVO will do the rest.

Follow disease progression

Glaucoma Tool Kit

Comprehensive glaucoma analytical tools for quantification of the Nerve Fiber Layer and Ganglion Cell Layer. The Disc Damage Likelihood Scale enables clinicians to precisely diagnose and monitor glaucoma for Optic Nerve Head analysis.

Comprehensive Hood report

Structure + Function

Our S+F report allows clinicians to understand the relationship between structural glaucoma damage and the functional impact on the patient’s field of vision. This provides a quick and comprehensive single-page report for glaucoma management.

Perform high-resolution posterior and anterior segment scans

Additional Scan Programs

Retina

  • 3D Volume Scan
  • Radial Line Scan
  • Raster Line Scan
  • Retina Cross Scan
  • High Resolution Line Scan

Disc

  • 3D Volume Scan
  • Radial Line Scan
  • High Resolution Line Scan

Central

  • 3D Volume Scan
  • Raster Line Scan
  • Full Range Line Scan

Anterior

  • 3D Volume Scan
  • Radial Line Scan
  • Raster Line Scan
  • Anterior Cross Scan
  • Anterior Line Scan
  • Anterior Chamber Full-Range Radial Scan
  • Anterior Chamber Full-Range Line Scan

Optional Software Modules

Angiography OCT

Angiography OCT provides an alternative to the traditional fluorescein method. Although OCT-A will not completely replace FA imaging, it is a quick and non-invasive tool. The software allows clinicians to observe, track and compare changes in the microvasculature of the retina in both eyes.

Ultra-Widefield Module

The UWF module provides a new wide perspective of imaging up to ~105º with a single scan. It allows the user to image the macular area along with the far periphery to capture the early stages of disease in the posterior part of the eye. The module allows 3D imaging for full analysis, averaging in enhancement mode, and angio OCT with the ability to visualise perfusion problems in the periphery.

Biometry OCT

B-OCT® is an excellent tool for any clinician who manages myopia control or performs cataract surgery. Biometry OCT provides a complete set of ocular parameters: Axial Length, Central Cornea Thickness Anterior Chamber Depth, Lens Thickness, Pupil size, and White to White.

IOL Calculation

IOL formulas allow the user to calculate IOL implant parameters. Our systems now support the latest IOL data base standard IOLCon.org so that you can always keep your library up-to-date.

Topography

Topography OCT is a pioneering way to provide detailed corneal curvature maps. Anterior, Posterior surfaces and Corneal Thickness provide the True Net Curvature information. T-OCT™ is excellent when paired with the B-OCT® module for IOL surgery.

Brochure

REVO FC Brochure

Technical Specifications

 

FUNDUS CAMERA 

Type Non-mydriatic fundus camera
Photography type Color
Angle of view 45° ± 5%
Min. pupil size for fundus 3.3 mm
Camera 12.3 Megapixel
Photography Fundus (Retina, Central, Disc, Manual fixation), Anterior photo
Flash adjustment, Gain, Exposure Auto, Manual
Intensity levels High, Normal, Low

 

OPTICAL COHERENCE TOMOGRAPHY

Technology
Spectral Domain OCT
Light source SLED Wavelength 850 nm
Bandwidth 50 nm half bandwidth
Scanning speed 80 000 measurements per second
Axial resolution 2.8 μm digital, 5 μm in tissue
Transverse resolution 12 μm, typical 18 μm
Overall scan depth 2.8 mm / ~6 mm in Full Range mode
Min. pupil size for OCT 1.7 mm
Focus adjustment range -25 D to +25  D
Scan range Posterior 5 mm to 15 mm, Angio 3 mm to 9 mm,
Anterior 3 mm to 18 mm
Scan types 3D, Angio¹, Full Range Radial, Full Range B-scan, Radial (HD), B-scan (HD), Raster (HD), Raster 21 (HD), Cross (HD), TOPO ¹, Biometry AL¹
Fundus alignment IR, Live Fundus Reconstruction
Alignment method Fully automatic, Automatic, Manual
Fundus tracking Real time active, iTracking
Retina analysis Retina thickness, Inner Retinal thickness, Outer Retinal thickness, RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness, RPE deformation, MZ/EZ-RPE thickness
Angiography OCT¹ Vitreous, Retina, Choroid, Superficial Plexus, RPCP, Deep Plexus, Outer Retina, Choriocapilaries, Depth Coded, SVC, DVC, ICP, DCP, Custom, Enface, FAZ, VFA, NFA,
Quantifi cation: Vessel Area Density, Skeleton Area Density, Thickness map
Glaucoma analysis RNFL, ONH morphology, DDLS, OU and Hemisphere asymmetry, Ganglion analysis as RNFL+GCL+IP and GCL+IPL,
Structure + Function ³
Angiography mosaic Acquistion method: Auto, Manual
Mosaic modes: 10 mm x 6 mm, Manual up to 12 images
Biometry OCT ¹ AL, CCT, ACD, LT, P, WTW
IOL Calculator ² IOL Formulas: Hoffer Q, Holladay I, Haigis, Theoretical T, Regression II
Corneal Topography Map ¹ Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior, Total], Net Map, Axial True Net, Equivalent Keratometer, Elevation [Anterior, Posterior], Height, KPI (Keratoconus Prediction Index)
Anterior
(no lens/adapter required)
Anterior Chamber Radial, Anterior Chamber B-scan, Pachymetry, Epithelium map, Stroma map, Angle Assessment, AIOP, AOD 500/750, TISA 500/750, Angle to Angle view
Connectivity DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking
Fixation target OLED display (the target shape and position can be changed), External fixation arm
Dimensions (LxWxH) / Weight 479 mm × 367 mm × 493 mm / 30 kg
Power supply / Consumption 100 V to 240 V, 50/60 Hz / 90 VA to 110 VA

UWF LENS ⁴

Scan angle ~105° ⁵
Working distance 15 mm
Scan types 3D, Radial, Line, Angio¹, Full Ranger Radial, Full Range Line
Fundus tracking iTracking
Overall scan depth 2.6 mm / 5.4 mm in Full Range mode

 

¹ An optional software module
² The Biometry module and a separate license for the IOL Calculator are required
³ Via connection with PTS software version 3.4 or higher
⁴ Ultra-Wide Field imaging is available with the optional UWF lens
⁵ Measured from the center of the eye